Question: Do I Need Fire Resistant Drywall?

Is all drywall fire rated?

Drywall is relatively fireproof, but manufacturing processes such as adding glass fibers can increase the resistance.

Drywall is relatively fire resistant.

It’s composed of gypsum pressed between two sheets of thick paper.

Gypsum is a soft mineral that by itself is not flammable..

What’s the fire rating on 5/8 drywall?

1 hourNorm Abram replies: The 5/8-inch, “fire-code” drywall (called Type X) increases a wall’s fire rating to a minimum of 1 hour, from the 30-minute rating for standard ½-inch drywall. And it’s not just thickness that makes the difference.

How thick is a 2 hour fire rated wall?

3 1/5 inchesThe fire-resistance rating of concrete masonry walls depends on the type of aggregate used in the units. A 2-hour rating can be achieved by a wall with an equivalent thickness of as little as 3 1/5 inches when expanded slag or pumice is used or 4 1/2 inches when siliceous gravel is used as the aggregate.

What is code for drywall in a garage?

The IRC code requires 1/2″ rock on the garage side of the garage walls and any supporting structure (steel posts, stud walls, etc). If there is habitable space above the garage then 5/8″ is required on the ceiling and any horizontal members such as steel beams.

What is the difference between sheetrock and drywall?

Put a bit differently: Drywall and sheetrock are really the same thing. Drywall is a panel made of gypsum plaster pressed between two thick sheets of paper. Sheetrock is a brand of drywall patented by the US Gypsum Company.

What is fire resistant drywall?

Fireproof drywall is the pejorative term; its industry name is Type X drywall. The thickness of this drywall is 5/8-inch, including all layers. Glass fibers are added to the board to help it retard fire. Also, because it is denser than normal gypsum-and-paper drywall, it takes longer for the fire to degrade it.

What is the most fire resistant material?

Scientists discovered that tantalum carbide (TaC) and hafnium carbide (HfC) materials are capable of resisting temperatures of nearly 4000 degrees Celsius. A team of researchers from Imperial College London identified that the melting point of hafnium carbide is the highest ever recorded for a material.

Does it matter if you drywall ceiling or walls first?

Hang drywall on the ceiling first, then the walls. Check the ceiling for bowed joists using a 4-ft. … “If the ceiling is 12 ft. long, there’s no sense in using an 8-ft.

What is 1 hour fire rated wall?

According to the Engineered Wood Association, a one-hour rating indicates that a wall constructed in a manner similar to the one tested will contain flames and high temperatures, and support its full load, for at least one hour after the fire begins.

What does 1 hour fire rating mean?

A “one-hour” fire rating is given to an assembly consisting of various building materials that can resist the exposure of a standardized fire exposure for one hour. … A few acceptance criteria for the test stipulate that the fire from the gas-fired furnace cannot penetrate through the assembly during the test.

Where is fire rated sheetrock required?

Fire rated drywall is typically found on attached garage walls and ceilings that are adjacent to the main living area of the home. For commercial buildings, fire rated gypsum drywall is specified for most of the building walls and ceilings to meet building code requirements for fire partitions and assemblies.

How do you know if a wall is fire rated?

Open the door and look on the frame and the inside edge of the door next to the hinges. A fire rated door has a metal tag listing the fire rating of the door assembly. All openings through a fire rated wall MUST be sealed with a fire rated caulking (its red in color) so that no air (or flame) can pass through the wall.

What is a 2 hour fire rated wall?

Gypsum Board: Two (2) hour rated walls have two (2) layers of 5/8″ Type ‘X’ gypsum wallboard panels on each side of the steel studs. The “Fire Tape” product would be used as an alternative to conventional joint tape in specific systems when: 3.

How do you get a 2 hour fire rated wall?

Double the number of Type X sheets on the wall for a simple system installed over fire-resistant fiberglass insulation; each sheet of 5/8-inch Type X drywall is rated to resist fire for one hour, so two layers will produce a two-hour firewall.

Can you use 1/2 inch drywall ceiling?

1/2-inch: Half-inch drywall panels are the standard thickness for interior walls, as well as ceilings. 5/8-inch: These panels are commonly used for ceilings, or for walls that require a prescribed fire-resistant rating.